FEATURES
▪ Plate-form with 4 load cells, with low profile. It can be used in legal metrology.
▪ Installation on ground.
▪ Diamond plate 5/7 mm thick in steel.
▪ Steel framework, in cold formed sheet 3 mm thick.
▪ ZEMIC load cells H8C model OIML R-60 C3, in steel, IP67 protection.
▪ Junction box in stainless steel, IP64 protection.
▪ Lateral access to the junction box.
▪ 2 folding acces ramps included.
| Dimensions (mm) |
a | b | c | d | e | h |
|---|---|---|---|---|---|---|
| 1200x1200 | 1200 | 1200 | 2220 | 1336 | 1450 | 50 |
| 1500x1200 | 1500 | 1500 | 2520 | 1636 | 1450 | 50 |
| REFERENCE | DIMENSIONS (mm) | CAPACITY (kg) | FRACTION (g) |
|---|---|---|---|
| BVL1200 | 1200x1200 | 1500 |
500 |
| BVL1500 | 1500x1500 | 1500 |
500 |
| Accessories | |||
|---|---|---|---|
| Reference | Description equipment | ||
| CSP | Steel painted column (on ground) | ||